9kVA, Single Phase, Standby Diesel Generator with Perkins Engine with 400L Tank

Code: 416088

Print
Product Code
ED9PYE-400

Request a Quote Now

Click the link below to connect with our team.
We’ll help you define the technical requirements for your Standby Generator.

Request Quote

Precision-Built. Performance-Tested. Fast Turnaround.

Welling & Crossley Generators are assembled and tested in our advanced Melbourne facility, ensuring each unit meets the performance and reliability standards demanded by Australian conditions.

With a typical 5–10 day turnaround, our local assembly allows for rapid delivery without compromising on quality. Submit a quote request today, and our technical team will assess your requirements to configure the most suitable product for your application.

Where to Buy

Find Your Nearest Store
Technical Specifications
Brand Welling & Crossley
Product Type Standby Diesel Generator
Generator Type Single Phase
Engine Brand Perkins
Fuel Diesel
Tank Size 400L
Generator Rating (kVA) 1 to 20kVA
Description

The Welling & Crossley ED9PYE-400 9kVA Single Phase Standby Diesel Generator is a compact, canopy-enclosed diesel generator designed to provide reliable backup power when mains supply is unavailable. Powered by a trusted Perkins 403D-11G diesel engine and paired with a Crossley SLG series single bearing, 4-pole brushless alternator, this model is built for standby applications where dependable performance, long service life, and simple operation are essential.

This 400L tank variant is ideal for customers who need extended on-site fuel capacity and reduced refuelling frequency. The generator is supplied complete with a 400 litre bunded fuel tank, remote start/stop control system, auto-start control module, and weather protective acoustic canopy, making it a practical option for homes, farms, workshops, small commercial sites, rural properties, and essential equipment backup.

The acoustic canopy helps protect the generating set from the elements while reducing operating noise to approximately 70 dB(A) at 1 metre, or 63 dB(A) at 7 metres. The complete unit is mounted on a heavy duty fabricated steel base frame, with anti-vibration pads fitted between the engine, alternator, and frame to help isolate vibration and support smooth operation.

For safer and more practical diesel storage, the ED9PYE-400 includes a fully bunded fuel tank compliant with AS 1940-2004, providing secondary containment designed to help retain and recover spillage if required. The control panel includes an emergency stop button, and the battery charger helps maintain the generator so it is ready to start when needed.

The standard auto-start control module supports local or remote starting and provides key operating protection and monitoring functions, including alternator frequency and speed sensing, generator/load power monitoring, overload protection, accumulated power monitoring, engine speed protection, run-time scheduling, battery voltage monitoring, and static battery charging. It can also be configured to operate with an Automatic Transfer Switch for automatic standby power applications.

With its Perkins diesel engine, 400 litre bunded tank, acoustic canopy, Crossley brushless alternator, and remote start capability, the ED9PYE-400 is well suited to customers needing reliable single phase diesel standby power with extended fuel capacity for residential, rural, commercial, and light industrial applications.


Starting is remote or local to the machine with a push Start/Stop button and includes
  • Alternator frequency & speed sensing
  • Fully configurable via the interface or PC using USB
  • Generator/load power monitoring
  • Accumulated power monitoring
  • Generator overload protection
  • Fuel and start outputs
  • Engine speed protection
  • Engine run-time scheduler
  • Battery voltage monitoring
  • Static battery charger
Features
Weather-protective Acoustic Canopy

A weather-protective acoustic enclosure is included to protect and prolong the life of your generator. Finished using a powder coat paint finish, this acoustic canopy will reduce the noise level of the generating set to approximately 70 dB(A) at 1 metre from the machine (63 dB(A) @ 7 m).


Heavy-duty fabricated steel base frame

The complete generating set is mounted as a whole onto a heavy-duty fabricated steel base frame. Anti-vibration pads are fixed between the engine and alternator feet and the base frame, ensuring complete vibration isolation of the rotating assembly.


Bunded Fuel Tank (AS 1940-2004 compliant)

The fuel tank is fully bunded and complies fully with relevant sections in AS 1940-2004. It has a secondary containment compound with a capacity as big or bigger than that of the tank, and is made of surface-coated steel. This compound is designed to sufficiently retain spillage and enable recovery of any spillage. For more information regarding AS 1940-2004 compliance, refer to the standard or contact us.


Battery Charger

This trickle charge battery charger ensures that your generator can start up when needed. It has both 12v and 24v charging capabilities.


Control Panel with Emergency Stop button

This control panel monitors the controls of a single unit to achieve automatic start/stop, data measuring/monitoring, alarm protection and three remote systems (remote control, remote measuring and remote communication). The controller adopts a large liquid crystal display (LCD) and has a 32-bit microprocessor with precision parameters for measuring, fixed value adjustment, time setting and threshold adjustment.


Prime or Standby Power

Standby: kVA @ 0.8 pf. These ratings are applicable for supplying continuous electrical power (at variable loads) in the event of a utility power failure. No overload is permitted on these ratings. Minimum output from alternators is peak continuous rated (as defined in 1SO 8528-3 @ 27°C. Annual hour limitation: 500 hours).

Prime (continuous): kVA @ 0.8 pf. (Divide standby rating by 1.1). Available for continuous electrical output. There is no hour limitation. 10% overload is available for 1 hour in 12. The generating set and this specification are designed for environmental conditions of up to 27°C, up to 152.4 m above sea level and up to 60% relative humidity. Ratings at 0.8 pf. For ratings outside this range, please contact us.


Alternator Specifications
Alternator Model Crossley
Electric Power Single Phase
Active Rating 8.8kVA at 0.8pf (Standby)
Power 7.04kW
Voltage 240V
Frequency 50Hz

Engine Specifications
Engine Model Perkins 403D-11G
Engine Speed 1500rpm
Cylinder No. 3
Cubic Capacity 1.1L
Bore/Stroke 77 x 81mm
Compression Ratio 23.0:1
Aspiration Natural
Starter Voltage 12V
Flywheel (Max Continuous Power) 8kW
Combustion Air Flow 1m³/min
Cooling Air Flow 35m³/min
Cooling System Radiator Cooled
Heat Rejection to Cooling System 8kW
Exhaust Gas Flow 2.2m³/min
Exhaust Gas Temperature 550°C
Fuel Type Diesel
Fuel Tank Capacity 400L
Approx. Fuel Consumption (Continuous) 2.75L/hr
Approx. Fuel Consumption (Standby) 3.0L/hr

Generator Specifications
Dimensions (L x W x H) 1800 x 900 x 1500mm
Weight 1165kg
Product Range Brochure
Downloads
Product Information and Data Sheets
Download Product Information & Data Sheets v1.0