9kVA, Single Phase, Standby Diesel Generator with Perkins Engine in Canopy

Code: 416087

Print
Product Code
ED9PYE

Request a Quote Now

Click the link below to connect with our team.
We’ll help you define the technical requirements for your Standby Generator.

Request Quote

Precision-Built. Performance-Tested. Fast Turnaround.

Welling & Crossley Generators are assembled and tested in our advanced Melbourne facility, ensuring each unit meets the performance and reliability standards demanded by Australian conditions.

With a typical 5–10 day turnaround, our local assembly allows for rapid delivery without compromising on quality. Submit a quote request today, and our technical team will assess your requirements to configure the most suitable product for your application.

Where to Buy

Find Your Nearest Store
Technical Specifications
Brand Welling & Crossley
Product Type Standby Diesel Generator
Generator Type Single Phase
Engine Brand Perkins
Fuel Diesel
Tank Size 90L
Generator Rating (kVA) 1 to 20kVA
Description

The Welling & Crossley ED9PYE 9kVA Single Phase Standby Diesel Generator is a compact, canopy-enclosed backup power solution designed to provide dependable single phase power when mains supply is unavailable. Powered by a trusted Perkins 403D-11G diesel engine and paired with a Crossley SLG series single bearing, 4-pole brushless alternator, this generator is built for standby applications where reliability, quiet operation, and long service life are essential.

Designed as a fully integrated Welling & Crossley power generation system, the ED9PYE comes complete with a remote start/stop control system, 90 litre diesel fuel tank, auto-start control module, and weather protective acoustic canopy. This makes it well suited to residential, rural, commercial, workshop, and light industrial backup power applications where a reliable diesel standby generator is required.

The acoustic canopy helps protect the generating set from the elements while reducing operating noise to approximately 70 dB(A) at 1 metre, or 63 dB(A) at 7 metres. The generator is mounted on a heavy duty fabricated steel base frame, with anti-vibration pads fitted between the engine, alternator, and frame to help isolate vibration and support smooth operation.

For safer and more practical diesel storage, the ED9PYE includes a fully bunded fuel tank compliant with AS 1940-2004, providing secondary containment to help manage spills on site. The unit also includes battery charging support and a control panel with emergency stop functionality.

The standard auto-start control module allows the generator to be started locally or remotely and provides key operating protection and monitoring functions, including generator/load power monitoring, accumulated power monitoring, overload protection, engine speed protection, run-time scheduling, battery voltage monitoring, and static battery charging. It can also be configured to operate with an Automatic Transfer Switch for automatic standby power applications.

With its Perkins diesel engine, Crossley brushless alternator, acoustic canopy, bunded tank, and remote start capability, the ED9PYE is a practical choice for customers needing reliable single phase diesel standby power for homes, farms, workshops, small businesses, and essential equipment backup.


Starting is remote or local to the machine with a push Start/Stop button and includes
  • Alternator frequency & speed sensing
  • Fully configurable via the interface or PC using USB
  • Generator/load power monitoring
  • Accumulated power monitoring
  • Generator overload protection
  • Fuel and start outputs
  • Engine speed protection
  • Engine run-time scheduler
  • Battery voltage monitoring
  • Static battery charger
Features
Weather-protective Acoustic Canopy

A weather-protective acoustic enclosure is included to protect and prolong the life of your generator. Finished using a powder coat paint finish, this acoustic canopy will reduce the noise level of the generating set to approximately 70 dB(A) at 1 metre from the machine (63 dB(A) @ 7 m).


Heavy-duty fabricated steel base frame

The complete generating set is mounted as a whole onto a heavy-duty fabricated steel base frame. Anti-vibration pads are fixed between the engine and alternator feet and the base frame, ensuring complete vibration isolation of the rotating assembly.


Bunded Fuel Tank (AS 1940-2004 compliant)

The fuel tank is fully bunded and complies fully with relevant sections in AS 1940-2004. It has a secondary containment compound with a capacity as big or bigger than that of the tank, and is made of surface-coated steel. This compound is designed to sufficiently retain spillage and enable recovery of any spillage. For more information regarding AS 1940-2004 compliance, refer to the standard or contact us.


Battery Charger

This trickle charge battery charger ensures that your generator can start up when needed. It has both 12v and 24v charging capabilities.


Control Panel with Emergency Stop button

This control panel monitors the controls of a single unit to achieve automatic start/stop, data measuring/monitoring, alarm protection and three remote systems (remote control, remote measuring and remote communication). The controller adopts a large liquid crystal display (LCD) and has a 32-bit microprocessor with precision parameters for measuring, fixed value adjustment, time setting and threshold adjustment.


Prime or Standby Power

Standby: kVA @ 0.8 pf. These ratings are applicable for supplying continuous electrical power (at variable loads) in the event of a utility power failure. No overload is permitted on these ratings. Minimum output from alternators is peak continuous rated (as defined in 1SO 8528-3 @ 27°C. Annual hour limitation: 500 hours).

Prime (continuous): kVA @ 0.8 pf. (Divide standby rating by 1.1). Available for continuous electrical output. There is no hour limitation. 10% overload is available for 1 hour in 12. The generating set and this specification are designed for environmental conditions of up to 27°C, up to 152.4 m above sea level and up to 60% relative humidity. Ratings at 0.8 pf. For ratings outside this range, please contact us.


Alternator Specifications
Alternator Model Crossley
Electric Power Single Phase
Active Rating 8.8kVA at 0.8pf (Standby)
Power 7.04 kW
Voltage 240V
Frequency 50Hz

Engine Specifications
Engine Model Perkins 403D-11G
Engine Speed 1500 rpm
Cylinder No. 3
Cubic Capacity 1.1 L
Bore/Stroke 77 x 81 mm
Compression Ratio 23.0:1
Aspiration Natural
Starter Voltage 12V
Flywheel (Max Continuous Power) 8 kW
Combustion Air Flow 1 m³/min
Cooling Air Flow 35 m³/min
Cooling System Radiator Cooled
Heat Rejection to Cooling System 8kW
Exhaust Gas Flow 2.2 m³/min
Exhaust Gas Temperature 550°C
Fuel Type Diesel
Fuel Tank Capacity 90 L
Approx. Fuel Consumption (Continuous) 2.75 L/hr
Approx. Fuel Consumption (Standby) 3.0 L/hr

Generator Specifications
Dimensions (L x W x H) 1800 x 900 x 1153 mm
Weight 700 kg
Product Range Brochure
Downloads
Product Information and Data Sheets
Download Product Information & Data Sheets v1.0